Diaphragm pumps use FAQs

Pneumatic diaphragm pump is now more widely, to be accepted by the public. In many companies, such as chemicals, spraying, ceramics and other factories have many diaphragm. Diaphragm pumps can be broadly divided into two categories, one is electric diaphragm pump, one is the pneumatic diaphragm pumps. But in order to get the most use of pneumatic diaphragm pumps. So here I am to talk about the experience of pneumatic diaphragm pumps little maintenance. I hope the majority of the equipment maintenance personnel to help. This article and want to play a valuable role. Let us come together to explore and improve together.

Frequently Asked Questions: 1. Pump weakness, slow pumping. This phenomenon generally have the following situations,

First, the gas supply pressure is reduced. First look at the intake pressure gauge, pressure of 4 to 7 kg is normal. Then check the air supply valve opening position, such as opening and closing a gas supply solenoid valve, then the check valve solenoid plastic sheet without damage, resulting in the plastic valve sheet can not be fully opened.

Second, muffler clogged, exhaust gas can not be fast, slow down the diaphragm plastic pump speed.

Third, water or excessive compressed air impurities. After entering the diaphragm with a clogged air intake valve, or stuck valve spool. Fourth, with the valve cover and down time due to constant attack by the spool valve cover damage resulting in leaks. Fifth, the internal axial pump seal ring wear four string gas.

Home About us Products Client Cases Services News Contact Us
Copyright © Jiekai Industrial Equipment Co., Ltd.   Tel: +86-769-22778262  Fax: +86-769-22778212